YORK® introduces YDAM – the next generation in highdensity cooling

Johnson Controls Unveils High-density Chiller for Multistory Data Centers

With up to 3.5MW of cooling, the YORK YDAM delivers up to 20% increased capacity density than other available solutions.

Johnson Controls (NYSE: JCI) has announced its newest innovation in data center thermal management, the YORK YDAM air-cooled magnetic bearing centrifugal chiller. The innovative chiller is purpose-built to overcome the complex space and site challenges in high-density, multistory data centers. Built around the company’s award-winning YORK YVAM chiller technology, YDAM delivers best-in-class cooling capacity within a compact footprint, helping data centers scale faster and more efficiently without consuming water.

Due to increasing land constraints, multistory data centers and AI factories are becoming more common, increasing the density of the white space (where the racks live) by up to 10 times. Data center leaders therefore need higher density thermal management solutions to fit a shrinking roofline. With 3.5MW of cooling, YDAM delivers up to 20% increased capacity density in a more compact footprint than competing solutions. It fits on a 53-foot, standard flatbed trailer, making it easy to ship and minimizing transportation, rigging and lifting costs. Johnson Controls will begin shipments in late 2026.

“AI and high-performance computing are pushing data centers beyond traditional limits. Vertical sites can unlock new growth opportunities, but they demand thermal management solutions that deliver maximum cooling outputs in minimum space,” said Austin Domenici, vice president and general manager, Johnson Controls Global Data Center Solutions. “The impressive capacity and reduced footprint of YDAM could allow operators to cut the number of chillers on site by up to half, accelerating deployments and helping meet skilled onsite labor needs.”

jciy14509-YORK-Applied-DataCentersLandingPage-06-YVAM-D23a

YDAM chillers utilize YORK magnetic bearing compressors, allowing high chilled-fluid setpoints to support 45°C warm-water cooling of the latest generation of inference and training GPUs. They are also capable of operating with wide temperature differences, helping to reduce pump size and energy consumption – delivering CapEx and OpEx savings.  

Developed in the state-of-the-art Johnson Controls Advanced Development and Engineering Center (JADEC), YDAM chillers are tested against the most extreme real-world conditions, ensuring unmatched performance and reliability. YORK YDAM chillers are backed by a robust network of resources, including dedicated support teams and fast service and parts delivery.

Features

  • Packaged controls with full screen graphic display offers convenient system monitoring and trending
  • Low noise output (~65 dBA at 10 meters) for urban and sensitive installations
  • Variable speed drive with active front end offers zero-inrush current and meets IEEE-519 requirements
  • 710 – 950 TR (2500 – 3350 kW)
  • Performance is assured by AHRI certified performance
  • Optimized for R-1234ze and R-515B
  • Integral UPS and Quick Start allows YDAM to reach full load in as little as 3 minutes or less

More information about the YORK YDAM air-cooled magnetic bearing centrifugal chiller from Johnson Controls 

More information about York data center cooling solutions